According to the Center for Disease Control’s National Statistics Report, nearly half of the US population is considered to be either diabetic or prediabetic. For these individuals, an artificial pancreas—delivering insulin automatically based on real-time needs—could revolutionize diabetes care. While insulin pumps are already widely available, creating an artificial pancreas requires a seamless connection between the pump, a durable continuous glucose sensor, and algorithms capable of predicting patient habits. Today, we stand at the precipice of such a technology, but none of it would have been possible without the basic science research that began more than 3 decades ago.
The chemosensor breakthrough
Fluorescent chemosensors – compounds with a binding site, a fluorescent group, and a way to link the two – have been known since the mid-19th century for the detection of charged metal ions. However, the ability to “turn on” fluorescence in the presence of a non-charge analyte, especially in an aqueous environment, presents both a unique challenge as well as a powerful possibility for other sensing applications.
For example, suppose one could continuously monitor the concentration of biologically relevant sugars, like glucose, even though they are uncharged, by utilizing their reactive alcohol groups. In that case, imagining a way to achieve an artificial pancreas might be possible. This goal has long captured the imagination of scientists. In fact, the first article published in the Journal of the American Chemical Society (1879) reported the measurement of glucose concentrations.
Cracking the glucose code
In the early 1970s, Moore and colleagues showed that boronic acids could selectively bind to RNA and DNA components by forming transient boronic ester bonds with alcohol groups that differ in quantity and orientation. In an analogous manner, the author wondered if boronic acid substituted anthracenes (such as XX) could differentiate between biologically relevant sugars based on their unique differing alcohol patterns. By early 1990’s, the author successfully demonstrated detection of biologically relevant sugars using a boronic acid substituted anthracene, which fluoresced upon sugar complexation.
The detection of uncharged molecules, such as glucose, represents a significant opportunity for chemists. We here detail our invention of chemosensors that led to a continuous glucose monitor (CGM) used by diabetic patients.
Anthony Czarnik
Over the next several decades, researchers worked to enhance these sensors. The focus was on improving their selectivity for glucose over other sugars, increasing their stability under light exposure, and boosting fluorescence both before and after binding. Two key design changes proved critical: adding two boronic acid groups dramatically increased glucose selectivity, and linking these groups to amine-substituted phenyl rings maximized fluorescence changes upon binding.
From lab to market
The ability of sensors, such as XX, to respond to glucose in a concentration dependent manner rapidly piqued the interest of those in the medical device field, who recognized that fluorescence, which can be detectable through biological tissue, would be a particularly attractive readout for continuous biological monitoring.
In fact, three unique entities began working to incorporate diboronic acid glucose sensors into hydrogels that could be incorporated into implantable sensors for continuous glucose monitoring (CGM): Sensors in Medicine and Science Inc (SMSI) in the US (1997), GlySure Ltd in the UK (2006), and Terumo Corporation in Japan (2008). Of the three, only SMSI, now known as Senseonics, has been successful in bringing a non-enzymatic continuous glucose sensor to the market for consumer use.
Testing fluorescence in living systems
Before patients could use a sensor, the sensing molecule needed to be incorporated into a polymer hydrogel capable of producing a fluorescent signal in response to glucose levels in vivo. The first animal studies on this class of glucose sensors took place in the early 2000s while the author was the Chief Scientific Officer at SMSI. In these experiments, rabbits injected with hydrogel sensors were observed to fluorescence through their back skin in response to glucose levels.
This marked the first real proof that authors decade-old discovery could enable in vivo glucose monitoring. Witnessing the journey from foundational research to a technology that could improve the lives of millions is a rare and rewarding experience. While the author has since pursued other endeavours and holds no financial interests in SMSI, Senseonics, or their products, these early findings remain a milestone in developing continuous glucose monitoring.
Tackling biofouling challenges
Sensor lifetime is directly related to both the photostability of the sensor and any biological fouling that might occur upon implantation. Unlike enzymatic CGM sensors, which typically last 7–14 days, diboronic acid glucose sensors hold the promise of year-long use. However, the hydrogel capsule housing the sensor must withstand the body’s natural inflammatory response following implantation—a common challenge for all medical devices.
A variety of approaches have been evaluated to prevent biofouling and extend device lifetime. In the case of the CGM capsule, a dexamethasone acetate collar was attached to the capsule. Using dexamethasone acetate, a common synthetic corticosteroid that is found in a variety of medical devices, biofouling of the CGM sensor was prevented throughout the lifetime of the device without any evidence of dexamethasone in the patient’s blood.
Powering long-term glucose monitoring
Finally, the small capsule sensor must be powered, and the results must be communicated if a patient can act on those results. Early commercialization efforts utilized a sensor implanted in the wrist and a watch to achieve these goals; however, patients found this combination cumbersome. Relocating the sensor to the upper arm significantly improved comfort and introduced a removable receiver/power supply that could be worn on the arm.
Advances in communication technology further enhanced usability by enabling the receiver to sync directly with a smartphone application. This innovation allowed patients to monitor their blood sugar continuously using a familiar device. Crucially, this system eliminated the need for frequent sensor replacements every 7–14 days. The Senseonics Eversense CGM system gained initial approval in Europe and the US in 2016 (90-day: CE Mark – 2016; FDA approval – 2018, 180-day: CE Mark and FDA approval – 2022, and 365-day: FDA approval – 2024).
Getting closer to an artificial pancreas
In 2024, the Eversense 180-day CGM received an FDA approval as the first long-term integrated CGM (iCGM) system, allowing for the CGM to be linked directly to an insulin pump for automated delivery of insulin to the patient. While this system is still considered to be hybrid (i.e., the patient needs to provide a bolus of insulin near meals), its approval marks a significant milestone and moves us one step closer to a truly artificial pancreas; an achievement that stands to improve diabetes disease management for the ever-growing diabetes community.
So, what does the future hold? More discoveries will be made in basic research laboratories that hold the potential to dramatically impact human health. Yet, they will only do so if we have the vision to imagine what they might achieve and the patience and willingness to develop them.
🔬🧫🧪🔍🤓👩🔬🦠🔭📚
Journal reference
Czarnik, A. W., & James, T. D. (2024). Fluorescent Chemosensors in the Creation of a Commercially Available Continuous Glucose Monitor. ACS sensors, 9(12), 6320-6326. https://doi.org/10.1021/acssensors.4c02403